Thermometer and temperature calibration service
Thermometers, sensors, data loggers and controllers in the lab. Ovens, furnaces, autoclaves, incubators, freezers and baths at your site.
We calibrate instruments. We do not sell them.
Send your instrument list and we reply with a written quotation, including the return date for each item. Collection and return within the Klang Valley.
About this calibration
Method
Thermometers and sensors are compared with a reference thermometer in a stable bath or dry block at several temperatures. Chambers such as ovens, incubators and freezers are checked at your site with several sensors placed through the working space. Your quotation states the test points.
How often
Commonly every 12 months, or sooner for equipment that protects samples, vaccines or products. Your quality system, regulator or auditor sets the interval.
Your certificate
Records the reading against the reference at each point, the error and the measurement uncertainty; for chambers, the readings at each sensor position.
Need an accredited certificate? For many instruments on this page, a SAMM-accredited partner lab can issue an accredited certificate in its own name. We confirm which lab before you book.
Instruments in this category
| Instrument | Range | Where | Quote list |
|---|---|---|---|
| Thermometer, glass or digital | −20 to 50 °C | Laboratory | |
| Thermometer, glass or digital | 0–100 °C | Laboratory | |
| Thermometer, glass or digital | 0–300 °C | Laboratory | |
| RTD / PT100 sensor | −50 to 200 °C | Laboratory | |
| RTD / PT100 sensor | 200–600 °C | Laboratory | |
| Thermocouple, type K | 0–600 °C | Laboratory | |
| Thermocouple, type K | 600–1100 °C | Laboratory | |
| Thermocouple, type J | 0–750 °C | Laboratory | |
| Thermocouple, type T | −200 to 260 °C | Laboratory | |
| Thermocouple, types N, S, R, B | Range confirmed on quotation | Laboratory | |
| Temperature data logger | −40 to 85 °C | Laboratory | |
| Paperless recorder | Range confirmed on quotation | Laboratory | |
| Chart recorder | Range confirmed on quotation | Laboratory | |
| Temperature controller | Range confirmed on quotation | Laboratory | |
| Temperature indicator | Range confirmed on quotation | Laboratory or on site | |
| Oven / drying oven | Ambient to 300 °C | On site | |
| Muffle furnace | 300–1100 °C | On site | |
| Autoclave / steam steriliser | 100–140 °C | On site | |
| Incubator / stability chamber | 15–60 °C | On site | |
| Ultra-low temperature freezer | −80 to −40 °C | On site | |
| Walk-in cold room / refrigerator | 2–8 °C | On site | |
| Dry block calibrator | −25 to 650 °C | Laboratory | |
| Liquid bath, oil or water | Ambient to 250 °C | On site | |
| Laboratory water bath | 20–95 °C | On site | |
| Infrared thermometer / pyrometer | 50–500 °C | Laboratory | |
| Temperature transmitter (incl. HART, mA/V output) | −40 to 660 °C | Laboratory | |
| Thermostat / temperature switch | Range confirmed on quotation | Laboratory |
Ranges shown are typical; exact capability is confirmed on your quotation.